Parts

Relay Controls

  • Details
  • Specifications

Relay Controls contain a load timer, control relay, discharge delay timer, the pressure switch, terminal block, and circuit fuse.

At the beginning of the load cycle, the discharge relay timer locks the system into the discharge cycle for an adjustable time. If the control system pressure has not exceeded the setting of the pressure switch in the preset time, the system goes back into load cycle.

NEMA 4 enclosure
120 VAC or 12 VDC
Multi-contact arrangement
Standard 8-pin octel type base
5 amp silver contacts
Repeat accuracy plus or minus 2% under fixed conditions.
Relay Controls
904-02006 - RELAY 8 PIN 120VAC
904-02018 - RELAY 11 PIN 115 3PDT KRP14AG P&B
904-02046 - BULB 120MB 120VAC
904-02075 - TIMER 115 5 120 1MS-115A-145A -FXD
904-02078 - TIMER 115V 40 SECOND MDR115A4 Z40
904-02139 - POT 2.5M OHM RV4 NAY POTENTIOMETER
904-02146 - TIMER 115 MMS115A5X60A 4 POST
904-02198 - SWITCH 2 POS SELECTOR 800TH2A AB
904-02265 - POT 1.5M 404R-1611-NLP 0-180 SEC
904-02389 - SWITCH START BUTTON X-PROOF
904-02390 - SWITCH 5150P3-1-1P1 STOP BUTTON XP
904-02469 - RELAY RTE-P12 120VAC TIMING R ELAY
904-02542 - TIMER 8 PIN 120VAC 0-180 115A 4Z180